Description
Desco 19343 Mini Monitor
Mini Monitor – Continuos monitor for a single ESD safe workstation, equipped with visual alarm, audible alarm and stand-by mode.
It establishes and continuously monitors the path-to-ground integrity of ESD safe wristband and mat (or the wristband alone, by deactivating the mat monitoring circuit).
The high visibility of its illuminated housing ensures that any malfunctions are immediately noticed by the operator and supervisor: a green light indicates proper grounding, a red light accompanied by an audible alarm indicates an intermittent or failed connection, a blue light indicates the stand-by mode.
Desco product no.: 19343.
PLEASE NOTE: The video shows a Banana wristband connection, while the 19343 model is supplied with a Banana to Snap adapter (Male, 10 mm).
Specifications
- Grounds and monitors the benchtop mat without additional cables, thanks to its convenient screw fixing system
- A switch allows to deactivate the mat monitoring, in case your workstation does’nt have one
- Park Delay switch and ParkSnap™ connection – System that allows you to put the Mini Monitor into stand-by mode when you leave the workstation, without triggering the alarm: after touching the Park Delay switch (B), the operator has 8 seconds to detach the connection cable fron his wrist strap and connect it directly to the Mini Monitor via the ParkSnap™ connection (E), “parking” it temporarily
- Alarm reaction speed: < 50 milliseconds
- Audible alarm adjustment: sets the audible alarm volume from loud to louder
- Wave Distorsion Technology: provides stable continuous monitoring (versus pulsed or intermittent) of the wristband’s path-to-ground and the presence of its 1 megohm safety resistor
- 1.2 V Operator test voltage: reduces the risk of electrical overstress (EOS) for the handling of sensitive components
- Compliant with ANSI/ESD S20.20 and ESD TR1.0-01-0 regulations
- NIST calibration – National Institute of Standards and Technology (USA) – The certificate is downloadable directly from the Desco Europe website by entering your device’s model and serial no. – Certificate consists of: model, serial no., calibration date, technician’s signature. It does not include any other data. It is not a MIL/ANSI calibration and it does not refer to any other standards.
Feature legend (see the “Features and Components” box in image gallery):
- A) Connect here the power adapter supplied
- B) Park Delay switch – It starts an 8-second timer: during this time you can disconnect the wristband cable without activated the alarm
- C) Operator Led (Green= PASS, Red = FAIL, Blue = STAND BY)
- D) Mat LED (Green= PASS, Red = FAIL, Blue = STAND BY)
- E) ParkSnap™ connection (Male, 10 mm) – “Park” here your wristband cord to put the system into stand-by mode
- F) Operator connection (Banana) – Connect here your wristband, directly or via the Banana to Snap adapter supplied
- G) Turn On/Off audio settings and mat monitoring
- H) Threaded ground terminal: connects the worksurface mat to the electrical ground
- I) Threaded worksurface monitor terminal: verifies that the worksurface’s path-to-ground is less than 10 megaOhms.
Scope of supply: 19343 Mini Monitor with ParkSnap™ (Male 10 mm), Banana to Snap adapter (Male, 10 mm) for wristband connection, 2 x Countersunk washer, 2 x Flat head screw (6-32 x 3/8″), Power supply adapter 100-240 Vac with IEC C14 inlet (9 VDC).
ATTENTION: 220 V POWER CABLE NOT INCLUDED
Services and accessories available on request: 19344 Circular magnets for mounting without fixing screws (for workstations without mat), Power cable (200220 Europe, 200225 UK), Calibration service.